Abstract:Objective To establish an immunofluorescence assay ( IFA) method of detecting the mammalian orthoreovirus 3 ( Reo3) in animal-derived biological materials and biological products for human use. Methods Reo3-sensitive cells were screened. The virus TCID50 was titrated and antigen slides were prepared according to GB IFA. The best working concentration of IgG-FITC was titrated and the specificity,sensitivity and stability were tested. Results BSC-1 cells were selected as Japanese encephalitis virus ( JEV) -sensitive cells. The TCID50 of the virus was 10 - 5. 8·mL - 1. The best working concentration of the IgG-FITC was 1: 100. There was no cross-reactivity with ectromelia virus and mouse hepatitis virus. The tests of sensitivity and stability showed that the detection sensitivity was 1: 1280 at different time points. The lowest detected virus titer was 10 - 4. 1·mL - 1. Conclusions The established IFA method is good in sensitivity,specificity and stability,and can be used in detecting the Reo3 in animal-derived biological materials and biological products for human use.