Comparison between the quantitative and semi-quantitative fluorescence RT-PCR assays for the detection of XDH/XO mRNA expression in different organ tissues of rhesus monkey
CSTR:
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    Objective To analyze the differences between the semi-quantitative RT-PCR and real time quantitative fluorescence RT-PCR assays for detecting XDH/XO mRNA expression in various organ tissues of rhesus monkey, and provide useful reference in methodology of experimental studies. Total RNA was extracted from the myocardium, kidney, testis, skin, and liver tissues, respectively, for detecting XDH/XO mRNA expression in rhesus monkey by semi-quantitative RT-PCR and real time quantitative fluorescence RT-PCR assays. The sensitivity and specificity of the two assays were compared with each other using the same primer sequences and reference genes. Results The expressionof XDH/XO mRNA in different organ tissues were detected by both the two PCR assays. The sensitivity of quantitative fluorescence real-time RT-PCR for the XDH/XO mRNA expression in the liver tissue was 39 times higher than that by semi-quantitative RT-PCR. Conclusions Both the quantitative and semi-quantitative fluorescence RT-PCR assays can be used to detect the expression of XDH/XO mRNA in different organ tissues of rhesus monkey. The sensitivity of quantitative fluorescence real-time PCR assay is more sensitive than that of the semi-quantitative RT-PCR assay.