Design and Application of Energy Monitoring System for Laboratory Animal Facilities
Author:
Affiliation:

Laboratory Animal Center,Huazhong University of Science and Technology

  • Article
  • | |
  • Metrics
  • |
  • Reference [21]
  • | | | |
  • Comments
    Abstract:

    Objective The energy consumption of experimental animal facilities accounts for a significant proportion of the energy consumption in scientific research institutions, and its energy consumption characteristics are significantly different from those of ordinary buildings, thus requiring specialized monitoring and management. Method A set of energy consumption monitoring systems was designed for experimental animal facilities, and was deployed in the SPF-level experimental animal facility of Huazhong University of Science and Technology. Results After the system went online, it achieved real-time collection and recording of the facility"s electricity consumption data, and proposed energy-saving measures for three application scenarios. Conclusion The energy consumption monitoring system for experimental animal facilities has the characteristics of being reliable, efficient, and user-friendly, and has guiding significance and promotion value for the energy management work of experimental animal facilities.

    Reference
    [1] GUAN B, ZHANG T, LIU X. On-site performance investigation of liquid-desiccant air-conditioning system applied in laboratory rodent room: A comparative study [J]. Energ Buildings, 2021, 232: 110664.
    [2] LI S, LIU X, ZHANG T. Ammonia absorption performance of a liquid desiccant dehumidification system applied in laboratory rodent room [J]. Appl Therm Eng, 2021, 199: 117523.
    [3] 余俊祥, 林金成, 高克文, et al. 实验动物用房暖通空调系统节能策略研究 [J] 暖通空调, 2023, 53(12): 24-9.
    [4] LIU C, MA H, LIU S, et al. Heat recovery technology and energy-saving effect analysis apply to cleanroom exhaust waste heat characteristics [J]. Energ Buildings, 2024, 306: 113935.
    [5] 任尔媛. 某SPF级动物房空调系统节能措施效果分析 [J] 暖通空调, 2021, 51(06): 71-4.
    [6] 吴强, 尤军, 吴成, et al. 三维热管在实验动物设施除湿中的节能应用 [J] 实验动物与比较医学, 2020, 40(05): 437-9.
    [7] 闫辰, 尚晓松, 孙波, et al. 乙二醇热回收装置在实验动物设施运行中的节能效果 [J] 实验动物科学, 2022, 39(03): 45-50.
    [8] ZHUANG C, WANG S. An adaptive full-range decoupled ventilation strategy for buildings with spaces requiring strict humidity control and its applications in different climatic conditions [J]. Sustain Cities Soc, 2020, 52: 101838.
    [9] LIU J, ZHANG L, YANG J, et al. Study on pressure control and energy saving of cleanroom in purification air conditioning system [J]. Energ Buildings, 2021, 253: 111502.
    [10] 钟加晨, 王志毅, 吴强. 基于节能的实验动物人工环境气流组织数值模拟 [J] 中国比较医学杂志, 2021, 31(03): 104-10.
    [11] 王文涛, 郑功杭, 李先庭, et al. 利用室内空气循环净化降低实验动物房新风量的节能效果 [J] 制冷学报, 2021, 42(06): 1-7.
    [12] 龚光彩, 陈湘, 刘激扬, et al. 空气载能辐射空调系统在实验动物房中的应用分析 [J] 湖南大学学报(自然科学版), 2022, 49(03): 211-9.
    [13] SHAN K, WANG S. Energy efficient design and control of cleanroom environment control systems in subtropical regions – A comparative analysis and on-site validation [J]. Appl Energ 2017, 204: 582-95.
    [14] LOOMANS M G L C, MOLENAAR P C A, KORT H S M, et al. Energy demand reduction in pharmaceutical cleanrooms through optimization of ventilation [J]. Energ Buildings, 2019, 202: 109346.
    [15] ZHUANG C, SHAN K, WANG S. Coordinated demand-controlled ventilation strategy for energy-efficient operation in multi-zone cleanroom air-conditioning systems [J]. Build Environ, 2021, 191: 107588.
    [16] CHENG X, LI C, MA X, et al. Pressure gradient control in bidirectional switching between standby mode and production mode in biopharmaceutical cleanroom [J]. J Build Eng, 2023, 65: 105816.
    [17] 丁贤明, 周荣贵, 丁阳, et al. 能耗监管体系在实验动物设施应用和节能措施评价 [J] 实验动物与比较医学, 2011, 31(06): 453-8.
    [18] 唐利军, 徐国景, 张金明, et al. 实验动物建筑设施节能技术探讨 [J] 中国比较医学杂志, 2010, 20(01): 73-8.
    [19] 胡铖, 胡晓妍. 医院能耗监测平台的优化与思考 [J] 中国卫生产业, 2020, 17(05): 80-2.
    [20] 代丹, 林绿渊, 肖武, et al. 制药厂房洁净空调系统能耗监测及分析方法 [J] 暖通空调, 2021, 51(10): 33-8+2.
    [21] 支琴, 熊顺子, 彭华松. 基于能耗监测的高校实验室安全管理策略 [J] 实验室研究与探索, 2020, 39(07): 300-4.